PP 281 R
|
|
Measuring standard
Coefficient of linear expansion
|
Two-coordinate TITANID phase grating on glass; grating period 8 ?m
αtherm ? 8 · 10–6 K–1
|
|
Accuracy grade
|
±2 ?m
|
|
Measuring range
|
68 mm x 68 mm,
other measuring ranges upon request
|
|
Reference marks1)
|
One reference mark in each axis, 3 mm after beginning of measuring length
|
|
Interface
|
1 VPP
|
|
Signal period
|
4 ?m
|
|
Cutoff frequency –3 dB
|
≥ 300 kHz
|
|
Traversing speed
|
≤ 72 m/min
|
|
Interpolation error
Position noise RMS
|
±12 nm
2 nm (450 kHz)2)
|
|
Electrical connection
|
0.5 m cable with 15-pin D-sub connector (male); interface electronics in the connector
|
|
Cable length
|
See interface description, but ≤ 30 m (with HEIDENHAIN cable)
|
|
Voltage supply
|
DC 5 V ±0.25 V
|
|
Current consumption
|
< 185 mA per axis
|
|
Vibration 55 Hz to 2000 Hz
Shock 11 ms
|
≤ 80 m/s2 (EN 60 068-2-6)
≤ 100 m/s2 (EN 60 068-2-27)
|
|
Operating temperature
|
0 °C to 50 °C
|
|
Mass Scanning head
Grid plate
Connecting cable
Connector
|
170 g (without cable)
75 g
37 g/m
140 g
|
|
1) The reference mark signal deviates in its zero crossovers from the interface specification (see Mounting Instructions)