A400系列德國陽光蓄電池參數:
|
型號
|
防火等級
|
電壓 V
|
額定容量(Ah,C10, 1.80V,25℃)
|
長 mm
|
寬 mm
|
高 mm
|
約重 kg
|
|
A412/180 A
|
UL94-HB或V0
|
12
|
185
|
518
|
274
|
238
|
64
|
|
A412/180 F10
|
UL94-HB或V0
|
12
|
185
|
518
|
274
|
244
|
64.5
|
|
A406/165 F10
|
UL94-HB或V0
|
6
|
170
|
244
|
190
|
282
|
28.5
|
|
A406/165 A
|
UL94-HB或V0
|
6
|
170
|
244
|
190
|
275
|
28
|
|
A412/120 F10
|
UL94-HB或V0
|
12
|
124
|
513
|
223
|
223
|
46
|
|
A412/120 A
|
UL94-HB或V0
|
12
|
124
|
513
|
223
|
223
|
45.5
|
|
A412/100 F10
|
UL94-HB或V0
|
12
|
103
|
513
|
189
|
223
|
37
|
|
A412/100 A
|
UL94-HB或V0
|
12
|
103
|
513
|
189
|
223
|
36.5
|
|
A412/90 F10
|
UL94-HB或V0
|
12
|
93
|
284
|
267
|
237
|
33.5
|
|
A412/90 A
|
UL94-HB或V0
|
12
|
93
|
284
|
267
|
230
|
33
|
|
A412/85 F10
|
UL94-HB或V0
|
12
|
88
|
204
|
244
|
276
|
32
|
|
A412/65 F10
|
UL94-HB或V0
|
12
|
67
|
353
|
175
|
220
|
23.5
|
|
A412/65 G6
|
UL94-HB或V0
|
12
|
67
|
353
|
175
|
190
|
23
|
|
A412/50 F10
|
UL94-HB或V0
|
12
|
52
|
278
|
175
|
196
|
19
|
|
A412/50 A
|
UL94-HB或V0
|
12
|
52
|
278
|
175
|
190
|
18.5
|
|
A412/50 G6
|
UL94-HB或V0
|
12
|
52
|
278
|
175
|
190
|
18.5
|
|
A412/32 F10
|
UL94-HB或V0
|
12
|
33
|
210
|
175
|
181
|
14.1
|
|
A412/32 G6
|
UL94-HB或V0
|
12
|
33
|
210
|
175
|
175
|
13.6
|
|
A412/20 G5
|
UL94-HB或V0
|
12
|
21
|
167
|
176
|
126
|
9
|
|
A412/12 SR
|
UL94-HB或V0
|
12
|
12.5
|
181
|
76
|
156
|
5.6
|
|
A412/8.5 SR
|
UL94-HB或V0
|
12
|
8.8
|
152
|
98
|
98
|
3.6
|
|
A412/5.5 SR
|
UL94-HB或V0
|
12
|
5.8
|
152
|
66
|
98
|
2.5
|
德國陽光蓄電池12v65ah今日價格
德國陽光蓄電池容量的測量
方法1:離線式測量法
a、將脫離供電系統的蓄電池組充滿電后靜置1—24h,在環境溫度為25℃±5℃的條件下開始放電;
b、放電開始前應測蓄電池的端電壓,放電期間應測記蓄電池的放電電流,時間及環境溫度,放電電流波動不得超過規定值的1%;
c、放電期間應測蓄電池端電壓及室溫,測量時間間隔為:10h率放電1h,3h率放電0.5h,1h率放電10min,在放電末期要隨時測量,以便準確地確定達到放電終止電壓的時間;
d、放電電流乘以放電時間即為蓄電池組的容量,蓄電池不按10小時率放電時或環境
溫度不是25℃時,則應將實際測量的容量換算成25℃時的容量;
e、放電結束后,要對蓄電池組充電,充入電量應是放電電量的1.2倍。
方法2:在線式測量法
a、在供電系統中,關掉整流器由蓄電池組放電供給通信設備,在蓄電池組放電時找出蓄電池組中電壓最低,容量最差的一只電池來作為容量試驗的對象;
b、打開整流器對蓄電池組進行充電,等蓄電池組充滿后穩定1小時以上;
c、對a中放電時找出的最差的那只電池進行10小時率放電試驗,放電前后要測量該只電池的端電壓、溫度、放電時間和室溫。以后每隔1h測試一次,放電快到終止電壓時,應隨時測試,以便準確記錄放電時間:
d、放電時間乘以放電電流即為該電池的容量,當室溫不是25℃時,應按式(1)換算成25℃時的容量;
e、放電試驗結束后用充電機對該只電池進行充電,恢復其容量;
f、根據測量的數據繪制放電曲線;
方法3:核對性容量試驗法
為了能隨時掌握蓄電池組的大致容量,進行核對性放電試驗是必要的,其方法是:
a、在直流供電系統中,關閉開關電源,讓蓄電池對通信設備供電,蓄電池組放電前后要測試每只電池的端壓、溫度、比重、室溫和放電時間、放出額定容量的30%—40%為止;
b、放電結束后,要對蓄電池充電;
c、根據測試的數據作出放電曲線,留作以再次測試時做比較;
注意事項:
上述3種蓄電池的容量試驗方法,是日常維護中常用的方法,但無論哪種方法,在容量測試期間通信安全都會受到一定的威脅。因此在做容量試驗時要防止市電中斷,備用發電組應處于良好狀態
|
型號
|
編號
|
電壓
|
C10
1.80
VpC
20℃
Ah
|
短路電流
(IEC896/2)
|
長
mm
|
寬
mm
|
高
mm
|
高
(含頂蓋)
mm
|
高
(含端子)
mm
|
重量
Kg.
|
內阻
(IEC896/2)
mOhm
|
最大負載
A
|
最大短路電流
(5秒)
A
|
端子
|
|
A412/65 G6
|
NGA4120065HS0BA
|
12
|
65
|
1414
|
353
|
175
|
190
|
190
|
190
|
24.6
|
9
|
440
|
1500
|
G-M6
|
恒電流放電參數表(20℃ 安培)
|
編號
|
型號
|
電壓
|
5min
|
10min
|
15min
|
20min
|
30min
|
45min
|
1h
|
2h
|
3h
|
4h
|
5h
|
8h
|
10h
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.85
|
102.0
|
77.0
|
63.0
|
56.0
|
48.0
|
42.0
|
36.0
|
22.0
|
15.9
|
12.9
|
10.9
|
7.3
|
6.2
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.80
|
120.0
|
95.0
|
76.0
|
64.0
|
52.0
|
45.0
|
39.0
|
23.0
|
16.7
|
13.4
|
11.3
|
7.6
|
6.5
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.75
|
134.0
|
107.0
|
84.0
|
70.0
|
56.0
|
48.0
|
41.0
|
24.0
|
17.1
|
13.6
|
11.4
|
7.7
|
6.5
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.70
|
148.0
|
111.0
|
89.0
|
73.0
|
57.0
|
49.0
|
41.0
|
24.0
|
17.3
|
13.7
|
11.5
|
7.7
|
6.5
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.65
|
161.0
|
114.0
|
91.0
|
75.0
|
57.0
|
49.0
|
42.0
|
24.0
|
17.3
|
13.7
|
11.5
|
7.7
|
6.5
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.60
|
170.0
|
116.0
|
92.0
|
76.0
|
58.0
|
49.0
|
42.0
|
24.0
|
17.3
|
13.8
|
11.5
|
7.7
|
6.5
|
恒功率放電參數表(20℃ 瓦/單體)
|
編號
|
型號
|
電壓
|
2min
|
3min
|
5min
|
7min
|
10min
|
15min
|
20min
|
30min
|
45min
|
1h
|
2h
|
3h
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.85
|
1,440.0
|
1,342.0
|
1,221.0
|
1,137.0
|
1,025.0
|
867.0
|
759.0
|
635.0
|
482.0
|
396.0
|
239.0
|
175.0
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.80
|
1,702.0
|
1,601.0
|
1,430.0
|
1,296.0
|
1,158.0
|
977.0
|
834.0
|
690.0
|
516.0
|
420.0
|
260.0
|
190.0
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.75
|
1,968.0
|
1,830.0
|
1,620.0
|
1,447.0
|
1,268.0
|
1,054.0
|
886.0
|
714.0
|
534.0
|
432.0
|
270.0
|
193.0
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.70
|
2,191.0
|
2,009.0
|
1,762.0
|
1,570.0
|
1,323.0
|
1,100.0
|
916.0
|
723.0
|
541.0
|
437.0
|
270.0
|
194.0
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.65
|
2,419.0
|
2,214.0
|
1,874.0
|
1,658.0
|
1,371.0
|
1,125.0
|
932.0
|
727.0
|
545.0
|
439.0
|
271.0
|
195.0
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.60
|
2,603.0
|
2,402.0
|
1,962.0
|
1,713.0
|
1,400.0
|
1,137.0
|
940.0
|
729.0
|
547.0
|
440.0
|
272.0
|
196.0
|